en
de fr es

Deutschland

Italia

España

United Kingdom

United States

Lietuva

Thermion 2 XG
Manual
Thermion 2 XG

Table of contents
How to Zero

How to Zero

Zeroing at a temperature close to the riflescope’s operating temperature is recommended.

Step 1. Take a shot

1. Shooting from a benchrest is recommended.

2. Set a target at a known distance.

3. Adjust the riflescope according to the Powering on and Image Setting section.

4. Select the zeroing profile (see Reticle & Zeroing  -> Zeroing Profile  main menu item)

5. Point the rifle at the center of the target and shoot.


Step 2. Align the reticle with the point of impact

1. Press and hold the controller button (6) to enter the main menu.

2. Add the distance you are aiming at (e.g. 100 meters): Reticle & Zeroing  -> Add New Distance . Select the value for each distance digit by rotating the controller ring (6). Press the controller button (6) briefly to switch between digits. After setting the required distance, press and hold the controller button (6) to save it.

3. After adding the distance, it will switch to the Zeroing parameters settings menu . An auxiliary cross will appear in the center of the display, and X and Y coordinates of the auxiliary cross will appear in the upper right corner.

4. Press the controller button (6) briefly to enter the Windage/Elevation  submenu.

5. While holding the reticle at the aiming point, move the auxiliary cross  until it is aligned with the impact point by rotating the controller ring (6)

6. To change the direction of the auxiliary cross movement from horizontal to vertical, press the controller button (6) briefly.


Zoom Zeroing function:

To improve the accuracy of zeroing, you can change the magnification in the menu . The larger the magnification, the smaller the step of shifting the reticle on the display relative to the image from the sensor.

Model

XG50

Click value, mm@100 m – when magnifying, x

15 mm – 3х

7.5 mm – 6х

3.75 mm – 12х

1.86 mm – 24х

 

One-shot "Freeze Zeroing" function:

Using the Freeze function allows you to make adjustments without the need to hold the rifle precisely at the initial aiming point – freezing the zeroing screen (refer to Reticle & Zeroing  menu item => Distance submenu => Zeroing Parameters Settings  submenu => Freeze submenu or short pressing of the REC (4) button. The image will “freeze” and the  icon will appear.


Step 3. Save the coordinates

1. Press and hold the controller button (6) to save a new position for the reticle. The reticle will be aligned with the impact point and it will exit the Windage/Elevation submenu.

2. Press and hold the controller button (6) again to exit the zeroing settings menu - the message “Zeroing coordinates saved” appears, confirming the successful operation.

3. Fire a second shot - now the point of impact and the aiming point must be matched.


Notes:

  • After zeroing, the reticle may not be in the center of the display.
  • The range of movement of the riflescope reticle allows you to successfully zero the riflescope, even on mounts that are far from ideal, minimizing the possible disadvantages of the mounts. The better the mount is installed, the less you have to move the reticle. We recommend mounting the riflescope as low as possible.