Possible cause
Battery Pack is discharged.
Solution
Charge the Battery Pack.
Solution
In case of any malfunctions during operation, try resetting the device by long pressing the ON/OFF button for 10 seconds.
Possible cause
The USB cable is damaged.
Solution
Replace the USB cable.
Possible cause
External power supply is discharged.
Solution
Charge the external power supply.
Possible cause
Calibration is required.
Solution
Perform the calibration according to Microbolometer Calibration section.
Solution
If the image does not clear after calibration, you need to recalibrate.
Possible cause
After turning on the device, it takes some time for the sensor temperature to stabilize. This is normal and is not a defect.
Possible cause
Brightness or contrast level is too low.
Solution
Adjust the brightness or contrast.
Possible cause
Problems described may arise in adverse weather conditions (snow, rain, fog, etc.).
Possible cause
Password in the device was changed.
Solution
Delete network and connect again inserting the password saved in the device.
Possible cause
There are too many Wi-Fi networks in the area device is located which may cause signal interference.
Solution
To ensure stable Wi-Fi performance, move the scope to an area with few or no Wi-Fi networks.
More information on solving problems with connection by following the links: Stream Vision FAQ, Stream Vision 2 FAQ.
Possible cause
The device is beyond reliable Wi-Fi range. There are obstacles between the device and the signal receiver (i.e. concrete walls).
Solution
Place the device in line-of-sight and within range of the Wi-Fi signal.
More information on solving problems with connection by following the links: Stream Vision FAQ, Stream Vision 2 FAQ.
Possible cause
The device has accumulated static charge during operation.
Solution
As soon as the impact of the static charge is over, the device may reboot automatically. Alternatively, please turn off and restart the device.
Possible cause
Because of variations in thermal conductivity, objects (surrounding environment, background) under observation become warm more quickly at above-zero temperatures, which allows higher temperature contrast, so the quality of the image produced by a thermal imager will be better.
At low operating temperatures, objects under observation (background) normally cool down to roughly identical temperatures, which leads to reduced temperature contrast and to image quality (precision) degradation. This is normal for thermal imaging devices.
Possible cause
You are looking through glass.
Solution
Remove the glass or change the viewing position to avoid it.
Solution
To replace the USB cable, contact your local distributor.
Self-repair of the cable is prohibited.
The ability to use a USB cable from other manufacturers with the device may be limited.