en
es

Deutschland

Italia

España

United Kingdom

United States

Lietuva

Thermion
Manual
Thermion

Table of contents

Microbolometer Calibration

Calibration enables to equalize the microbolometer temperature and eliminate the image defects (such as vertical bars, phantom images etc.).

There are three calibration modes: manual (M), semi-automatic (SA) and automatic (A). Select the required mode in the Calibration Mode  item.

M mode (manual)

  • Close the lens cover (12) and press the ON//OFF (3) button briefly.
  • Open the cover after the calibration is completed.

SA mode (semi-automatic)

  • Press the ON//OFF (3) button briefly to activate calibration.
  • There is no need to close the lens cover (internal shutter covers the microbolometer).

A Mode (automatic)

  • The riflescope is calibrated autonomously according to the software algorithm.
  • There is no need to close the lens cover (internal shutter covers the microbolometer).
  • In this mode, the riflescope may be calibrated by the user with the ON//OFF (3) button.

Note: a display image freezes until the calibration is in progress.