Microbolometer Calibration

Calibration eliminates image flaws (such as vertical bars, phantom images, grainy field of view, etc.) by equalizing the microbolometer background temperature.

There are three calibration modes: manual (M), semi-automatic (SA) and automatic (А).

Select the desired mode in the menu option Calibration Mode .

Mode М (manual)

  • Close the lens cover.
  • Press briefly the ON/OFF (1) button.
  • Open the lens cover.

Mode SA (semi-automatic)

  • Press briefly the ON/OFF (1) button to calibrate.
  • You do not need to close the lens cover (the microbolometer is closed with the internal shutter automatically).

Mode А (automatic)

  • The device calibrates by itself according to the firmware algorithm.
  • You do not need to close the lens cover (the microbolometer is closed with the internal shutter automatically).
  • In the automatic mode, the user can calibrate the microbolometer with the ON/OFF (1) (in the SA mode) button.
  • In the automatic calibration mode, three seconds before automatic calibration a countdown timer is shown in place of the calibration mode icon.