Krypton FXG
Manual
Krypton FXG

Table of contents

Calibration Mode

Calibration mode selection.

There are three calibration modes: Manual, Semi-Automatic and Automatic.

  1. Press and hold the MENU (7) button to enter the main menu.
  2. Use the RIGHT (6)/LEFT (8) buttons to select the Calibration Mode  icon.
  3. Press the MENU (7) button briefly to enter the submenu.
  4. Use the RIGHT (6)/LEFT (8) buttons to select one of the calibration modes described below.
  5. Press the MENU (7) button briefly to confirm the selection.

Automatic (A). In this mode the firmware determines the need for calibration. The calibration process starts automatically.

Semi-Automatic (SA). The user determines the need for calibration based on the image quality and can action at a convenient time depending on the object being observed.

Manual (M). In the Manual (silent) calibration mode the user determines the need for calibration (as in SA mode) but the lens cover must be closed during calibration.