en
it

Deutschland

Italia

España

United Kingdom

United States

Lietuva

Thermion 2 Pro
Manual
Thermion 2 Pro

Table of contents

Powering on and Image Settings

  1. Remove the lens cover (12).
  2. Turn the unit on with a short press of the ON/OFF (3) button.
  3. Adjust the sharpness of the symbols on the display by rotating the dioptre adjustment ring of the eyepiece (2).
  4. Rotate the lens focus ring (11) to focus on the object being observed.
  5. Enter the main menu with a long press of the controller button (6) and select the desired Calibration Mode: manual (M), semi-automatic (SA) or automatic (A).
  6. Calibrate the image with a short press of the ON/OFF (3) button (when calibration mode SA or M has been selected). Close the lens cap before manual calibration.
  7. Activate the quick menu by briefly pressing the controller button (6) button to select the amplification level (“Normal” , “High” , “Ultra” ), adjust the brightness and contrast (see the Quick Menu section).
  8. Repeatedly press the ZOOM (5) button to change the magnification ratio of the riflescope. While the magnifying glass icon  is visible on the screen, rotate the controller ring (6) for smooth digital zooming from the current magnification.
  9. Power the device off with a long press of the ON/OFF (3) button.

Observation conditions: time of day, weather, different observation objects affect the image quality. Custom settings for brightness, display contrast as well as the function of adjusting the microbolometer sensitivity level will help to achieve the desired quality in a particular situation.​

Warning! Never point the lens at intensive energy sources such as laser radiation emitting devices or the sun. It can damage electronic components in the device. The warranty does not cover damage arising from failure to comply with operating instructions.