For technical support please contact support@pulsar-vision.com.
Answers to frequently asked questions about the devices can also be found in the FAQ section.
Possible cause
The battery is completely discharged.
Solution
Charge the battery.
Solution
In case of any malfunctions during operation, try resetting the device by long pressing the ON/OFF button for 10 seconds.
Possible cause
The USB cable is damaged.
Solution
Replace the USB cable.
Possible cause
The external power supply is discharged.
Solution
Charge the external power supply (if necessary).
Possible cause
Calibration is required.
Solution
Perform image calibration according to the Calibration Mode section of the manual.
Possible cause
Manual calibration has been performed with the lens cover open.
Solution
Check the Calibration Mode, close the lens cover and calibrate the device.
Solution
If the image does not clear after calibration, you need to recalibrate.
Possible cause
After turning on the device, it takes some time for the sensor temperature to stabilize. This is normal and is not a defect.
Possible cause
Brightness or contrast level is too low.
Solution
Adjust the brightness or contrast in the Quick Menu.
Possible cause
The device was exposed to static charges during operation.
Solution
When the exposure to static charges is over, the device may either reboot automatically or require to be switched off and on again.
Possible cause
You are looking through glass.
Solution
Remove the glass or change the viewing position to avoid it.
Possible cause
The attachment is configured so that after fitting onto an optical riflescope that had been properly zeroed, no adjustment of the aiming point is required.
Solution
Yet if point of impact change is observed after putting on the attachment, you can fix it with display position calibration procedure (see General Settings section).
Possible cause
These problems may occur during observation in adverse weather conditions (snow, rain, fog, etc.).
Possible cause
Device password has been changed.
Solution
Delete the network and connect again using the password saved in the device.
Possible cause
The device is in an area with too many Wi-Fi networks that may be causing signal interference.
Solution
To ensure a stable Wi-Fi connection, relocate the device to an area with fewer or no Wi-Fi networks.
Solution
Switch the device's Wi-Fi bandwidth.
Possible cause
The device has a 5 GHz network enabled, but the smartphone only supports 2.4 GHz.
Solution
Switch the device's Wi-Fi bandwidth to 2.4 GHz.
More information on solving problems with connection to Stream Vision 2 by following the link.
Possible cause
The smartphone or tablet is beyond reliable Wi-Fi range. There are obstacles between the device and the signal receiver (e.g. concrete walls).
Solution
Move the devices in line-of-sight and within range of the Wi-Fi signal.
More information on solving problems with connection to Stream Vision 2 by following the link.
Possible cause
In positive temperature conditions, objects being observed (surroundings and background) heat up differently because of thermal conductivity, thereby generating a high temperature contrast. Consequently, the image quality produced by the thermal imager will be better.
In low-temperature conditions, objects being observed (background) will cool down to roughly the same temperature, which leads to a greatly reduced temperature contrast and a degraded image quality. This is normal for all thermal imaging devices.
Possible cause
Algorithms that are used for image processing might sometimes cause traces of horizontal lines to temporarily appear on the image. This should not be considered as a critical error.
Possible cause
The Bluetooth module is not turned on.
Solution
Turn on the Bluetooth module according to the instructions (see the Bluetooth section).
Possible cause
The Remote control is not activated.
Solution
Activate the remote control according to instructions (see the Remote Control Activation section).
Possible cause
The Remote Control is out of range of the device.
Solution
Return to the device coverage area.
Possible cause
Remote control battery low.
Solution
Install a new CR2032 battery as follows: unscrew the screws on the rear cover of the Remote Control, remove the cover, install a new battery, and screw the cover with screws.
Possible cause
The status bar may be partially or completely invisible due to the optical zoom of your riflescope. The lower the magnification, the more you see.
Solution
Decrease the riflescope magnification.
Solution
Reduce the size of the interface by long pressing the DOWN/MODE (7) button.
Solution
You can use the Stream Vision 2 app to see the full status bar on your smartphone screen.
from Yukon Group 2024
This website uses cookies to ensure you get the best experience on our website.