en
es

Deutschland

Italia

España

United Kingdom

United States

Lietuva

Accolade 2 LRF Pro
Manual
Accolade 2 LRF Pro

Table of contents

Microbolometer Calibration

 

Calibration eliminates image flaws (such as vertical bars, phantom images, grainy field of view, etc.) by equalizing the microbolometer background temperature.

There are three calibration modes: manual (M), semi-automatic (SA) and automatic (А).

Select the desired mode in the menu option Calibration Mode .

Mode М (manual)

  • Close the lens cover.
  • Press briefly the ON/OFF (1) button.
  • Open the lens cover.

Mode SA (semi-automatic)

  • Press briefly the ON/OFF (1) button to calibrate.
  • You do not need to close the lens cover (the microbolometer is closed with the internal shutter automatically).

Mode А (automatic)

  • The device calibrates by itself according to the firmware algorithm.
  • You do not need to close the lens cover (the microbolometer is closed with the internal shutter automatically).
  • In the automatic mode, the user can calibrate the microbolometer with the ON/OFF (1) (in the SA mode) button.
  • In the automatic calibration mode, three seconds before automatic calibration a countdown timer is shown in place of the calibration mode icon.