en
de

Deutschland

Italia

España

United Kingdom

United States

Lietuva

Merger LRF
Manual
Merger LRF

Table of contents
Defective Pixel Repair

Defective Pixel Repair

When operating a thermal imager, defective (dead) pixels (bright or dark dots with constant brightness) may become visible on the microbolometer.

Defective pixels on the microbolometer can increase in size relative to the digital-zoom power.

Merger LRF thermal imaging binoculars allow the user to remove any defective pixels on the display, as well as cancel removal, via the device’s firmware.


Step 1. Enter the menu to fix the defective pixels

  1. Press and hold the MENU (9) button to enter the main menu.
  2. Use the UP (7)/DOWN (8) buttons to select the Defective Pixel Repair  menu item.
  3. Press briefly the MENU (9) to open the submenu.
  4. Select the Defective Pixel Repair option by briefly pressing the MENU (9) button.

Step 2. Select the defective pixel

  1. A marker will appear on the centre of the image.
  2. A “magnifier” will appear on the right side of the image – an enlarged image in a frame with a fixed marker , designed for easier detection of a defective pixel and to match the pixel with the marker, and horizontal and vertical arrows for X and Y axes showing the marker's movement .
  3. With a short press of the UP (7)/DOWN (8) buttons move the marker to align it with a defective pixel.
  4. Switch the direction of the marker from horizontal to vertical and vice versa with a short press of the MENU (9) button.
  5. Align the defective pixel with the fixed cross in the frame - the pixel should disappear.

Step 3. Remove the defective pixel

  1. Delete the defective pixel with a short press of the ON/OFF (4).
  2. Once the pixel has been successfully deleted an "OK" message will briefly appear on the screen.
  3. Then, by moving the marker across the image, you can delete the next defective pixel.
  4. Exit the Defective Pixel Repair submenu with a long press of the MENU (9).

Warning! On each of the two displays of the thermal imaging device, 1-2 pixels in the form of bright white or coloured (blue, red) dots are allowed. They are not removed and are not a defect.