en
de

Deutschland

Italia

España

United Kingdom

United States

Lietuva

Helion 2 XP
Manual
Helion 2 XP

Table of contents

Microbolometer Calibration

 

Calibration eliminates image flaws (such as vertical bars, phantom images, grainy field of view, etc.) by equalizing the microbolometer background temperature.

There are three calibration modes: Manual (M), Semi-Automatic (SA) and Automatic (A).

Select the desired mode in the menu option Calibration Mode .

M Mode (Manual).

  • Close the lens cover.
  • Press the ON/OFF (11) button briefly.
  • Having finished calibration, open the lens cover.

SA Mode (Semi-Automatic).

  • Calibration is activated with a short press of the ON/OFF (11) button.
  • You do not have to close the lens cover (the microbolometer is closed with an internal shutter automatically).

A Mode (Automatic).

  • The device calibrates by itself according to the firmware algorithm.
  • You do not have to close the lens cover (the microbolometer is closed with an internal shutter automatically).
  • User assisted calibration with the ON/OFF (11) button is also allowed in this mode (as in the Semi-Automatic mode).
  • In Automatic calibration mode a countdown timer will appear instead of the calibration mode icon 3 seconds before automatic calibration begins.